Thermally operated water valve, AVTA 15, G, 1/2 (003N0107)

Code: 003N0107
Not rated
€315,63 / pcs €260,85 excl. VAT Measure price:
In stock
Delivery to:
02.09.2026
Danfoss thermally operated water valve AVTA 15, connection G 1/2, Kv 1.9 m³/h (item no. 003N0107).

Detailed information

Product detailed description

The Danfoss AVTA 15 thermally operated water valve opens and closes water flow based on the temperature sensed by a capillary sensor, without requiring an external power source. It is typically used for cooling machines and equipment with water.

  • Connection: G 1/2 (ISO 228-1)
  • Kv flow coefficient: 1.9 m³/h
  • Body material: Brass
  • Media temperature range: -25 to 130 °C
  • Max. working pressure: 16 bar
  • Differential pressure range: 0–10 bar
  • Capillary tube length: 2300 mm
  • Suitable media: Neutral media
  • Approvals: EAC, LLC CDC TYSK, PED, RoHS, RoHS China

Additional parameters

Category: Ventily AVTA
Weight: 1.27 kg
EAN: 5702423015559
Medium temperature range [°C] [max]: 130
Cap. tube length fraction [in]: 90 9/16 in
Max. sensor temperature [°F]: 266.0
Connection standard: ISO 228-1
SCIP dossier no.: a698bb81-6c39-4d14-a29f-0fc686728af9
Charge type: Adsorption
Max. test pressure [psig]: 362.6
Capillary tube gland type: G
Medium temperature range [°C] [min]: -25
Capillary tube gland standard: ISO 228-1
Max. pressure on sensor [bar]: 25
Temperature range [°F] [min]: 50
Connection Internal/External: Internal
Serviceable: Water valve spare parts
Capillary tube gland size [in]: 1/2
Suitable for cooling (EF024798): FALSE
Max. test pressure [bar] Pe: 25.0
Product accessories: Generic accessories, Water valves accessories
Connection type: G
Connection size [in]: 1/2
Sensor size (Ø x L) [in]: 3/8 x 5 29/32 in
Body material: Brass
Differential pressure [psi] [min]: 0.000
Capillary tube gland Int/Ext: Internal
Orifice size [mm]: 15.00
Suitable for heating (EF024797): TRUE
Medium temperature range [°F] [min]: -13
Max. pressure on sensor [psig]: 362.6
Cv value [gal/min]: 2.200
China RoHS compliance: Yes
Packing format: Multi pack
Max. sensor temperature [°C]: 130
Kv value [m³/h]: 1.900
Approval: EAC, LLC CDC TYSK, PED, RoHS, RoHS China
Differential pressure [bar] [min]: 0.000
REACH Candidate List substances: Lead (CAS no. 7439-92-1)
Differential pressure [bar] [max]: 10.000
Opening configuration: Opens on rising sensor temp.
Contains batteries: No
Media: Neutral media
EU RoHS exemption clause: 6(b), 6(c)
EU RoHS compliance: Yes with exemptions
Max. Working Pressure [bar]: 16.0
Medium temperature range [°F] [max]: 266
Sensor size (Ø x L) [mm]: 9.5 x 150 mm
Orifice size fraction [in]: 3/5 in
Flow direction indicator: Embossed 1-way arrow
Differential pressure [psi] [max]: 145.000
Temperature range [°F] [max]: 176
SCIP dossier product name: AVTA FJVA
Temperature range [°C] [min]: 10
Temperature range [°C] [max]: 80
Quantity per packing format: 10
Max. Working Pressure [psig]: 232
Capillary tube length [mm]: 2300

Discussion

Be the first who will post an article to this item!

Do not fill out this field:

Security check

Vložením komentáře souhlasíte s podmínkami ochrany osobních údajů