Frequency converter FC-101, 15 KW, 380 - 480 VAC (137L5866)

Code: 137L5866
Not rated
€2 087,50 / pcs €1 725,21 excl. VAT Measure price:
Backorder
Danfoss FC-101 frequency converter, 15 KW / 20 HP, 380 - 480 VAC, three-phase, IP20 / Chassis (item no. 137L5866).

Detailed information

Product detailed description

Built specifically for HVAC. The Danfoss VLT® HVAC Basic Drive FC-101P15KT4E20HXXXCXX6S600XAXBXCXXXXDX frequency converter controls the speed of fans and pumps in heating, ventilation and air-conditioning systems so they deliver exactly the airflow or water flow needed - no more. That translates directly into lower energy bills.

Where does it fit? Air handling units, cooling towers and pump stations in buildings, where energy savings are the top priority.

Key specifications

  • Type code: FC-101P15KT4E20HXXXCXX6S600XAXBXCXXXXDX
  • Power: 15 KW / 20 HP
  • Supply voltage: 380 - 480 VAC
  • Supply type: three-phase
  • Enclosure rating: IP20 / Chassis
  • Frame size: H4
  • EMC/RFI filter: No RFI Filter
  • Brake chopper: no brake chopper
  • Control panel: no local control panel
  • Weight: 7.6 kg

Additional parameters

Category: VLT HVAC Drive - pro vzduchotechniku
Weight: 8.2 kg
EAN: 5715253533612
RFI Filter: HX||No RFI Filter##(HX) No RFI Filter
Calculated Package Weight: 0.300
Calculated Gross Weight [kg]: 7.900
Power Rating: P15K||(P15K) 15 KW / 20 HP##HP not Valid if T7 drive, HP usually one size down
Adaptation A: X||Standard Cable Entries
Vendor: ERR01||Cannot Determine Vendor
Typecode Part 2: XX6S600XAXBXCXXXXDX
Modelcode01: FC-101P15KT4E20HXXXC
Modelcode02: XX6S600XAXBXCXXXXDX
Producing plant: ERR01||Cannot Determine Vendor
Adaptation B: 6||UL61800-5-1 certification##6 indicates IEC/UL 61800-5-1 Compliance
Calculated Net Weight [kg]: 7.600
Delivering plant: ERR01||ERR01
Software Language Pack: X||Standard Language Pack##Software
Typecode Part 1: FC-101P15KT4E20HXXXC
Mains Option: X||No Mains Option
Product Group: FC-||VLT® HVAC Drive FC-
Enclosure: E20||(E20) IP20 / Chassis##Normal cabinet mounting A, B & C Frames
Frame Size: H4||H4
ECCN US: 3A999.a||3A999.a
Series: 101||101##Basic version
Product View (Switch): GLBL||Global (Standard)
C Option Software: XX||No software option##Configuration software for speed synchrnisation between drives
Coating PCB: C||Coated PCB
Product Catalog: NO_VIEW||NO VIEW
B Option: BX||No B Option
Cross-Plant Configurable Material: VLT® HVAC Basic Drive FC 101
LCP: X||No Loc. Cont. Panel
Brake - Safe Stop: X||No brake chopper
C0 Option MCO: CX||No C0 option
C1 Option: X||No C1 option
Phase: T||Three phase
ECCN EU: Y901||Y901
Software Release: S600||UL61800-5-1##S600 indicated dedicated SW for IEC/UL 61800-5-1 Compliance
Mains Voltage: 4||380 - 480 VAC
A Option: AX||No A Option
D Option: DX||No D option

Discussion

Be the first who will post an article to this item!

Do not fill out this field:

Security check

Vložením komentáře souhlasíte s podmínkami ochrany osobních údajů