Thermally operated water valve, AVTA 25, G, 1 (003N4183)

Code: 003N4183
Not rated
€464,44 / pcs €383,83 excl. VAT Measure price:
Backorder
Danfoss thermally operated water valve AVTA 25, connection G 1, Kv 5.5 m³/h (item no. 003N4183).

Detailed information

Product detailed description

The Danfoss AVTA 25 thermally operated water valve opens and closes water flow based on the temperature sensed by a capillary sensor, without requiring an external power source. It is typically used for cooling machines and equipment with water.

  • Connection: G 1 (ISO 228-1)
  • Kv flow coefficient: 5.5 m³/h
  • Body material: Brass
  • Media temperature range: -25 to 130 °C
  • Max. working pressure: 16 bar
  • Differential pressure range: 0–10 bar
  • Capillary tube length: 3000 mm
  • Suitable media: Neutral media
  • Approvals: EAC, LLC CDC TYSK, PED, RoHS, RoHS China

Additional parameters

Category: Ventily AVTA
Weight: 1.54 kg
EAN: 5702423023226
Medium temperature range [°C] [max]: 130
Cap. tube length fraction [in]: 118 1/8 in
Max. sensor temperature [°F]: 257.0
Connection standard: ISO 228-1
SCIP dossier no.: a698bb81-6c39-4d14-a29f-0fc686728af9
Charge type: Universal
Max. test pressure [psig]: 362.6
Capillary tube gland type: G
Medium temperature range [°C] [min]: -25
Capillary tube gland standard: ISO 228-1
Max. pressure on sensor [bar]: 25
Bypass (Ø) [mm]: 2.0
Temperature range [°F] [min]: 122
Connection Internal/External: Internal
Serviceable: Water valve spare parts
Capillary tube gland size [in]: 3/4
Max. test pressure [bar] Pe: 25.0
Product accessories: Generic accessories, Water valves accessories
Connection type: G
Connection size [in]: 1
Sensor size (Ø x L) [in]: 23/32 x 8 1/4 in
Body material: Brass
Differential pressure [psi] [min]: 0.000
Capillary tube gland Int/Ext: Internal
Orifice size [mm]: 25.00
Medium temperature range [°F] [min]: -13
Max. pressure on sensor [psig]: 362.6
Cv value [gal/min]: 6.400
China RoHS compliance: Yes
Packing format: Multi pack
Max. sensor temperature [°C]: 125
Kv value [m³/h]: 5.500
Approval: EAC, LLC CDC TYSK, PED, RoHS, RoHS China
Differential pressure [bar] [min]: 0.000
REACH Candidate List substances: Lead (CAS no. 7439-92-1)
Differential pressure [bar] [max]: 10.000
Opening configuration: Opens on rising sensor temp.
Contains batteries: No
Media: Neutral media
EU RoHS exemption clause: 6(b), 6(c)
EU RoHS compliance: Yes with exemptions
Max. Working Pressure [bar]: 16.0
Medium temperature range [°F] [max]: 266
Sensor size (Ø x L) [mm]: 18 x 210 mm
Orifice size fraction [in]: 1 in
Flow direction indicator: Embossed 1-way arrow
Differential pressure [psi] [max]: 145.000
Temperature range [°F] [max]: 194
SCIP dossier product name: AVTA FJVA
Temperature range [°C] [min]: 50
Temperature range [°C] [max]: 90
Quantity per packing format: 10
Max. Working Pressure [psig]: 232
Capillary tube length [mm]: 3000

Discussion

Be the first who will post an article to this item!